TlvHarmonicMeasurement: ObjectSchema<{
    measurement: FieldType<null | number | bigint>;
    order: FieldType<number>;
}> = ...

Type declaration

  • measurement: FieldType<null | number | bigint>

    This field shall be the measured value for the given harmonic order.

    For the Harmonic Currents attribute, this value is the most recently measured harmonic current reading in milliamps (mA). A positive value indicates that the measured harmonic current is positive, and a negative value indicates that the measured harmonic current is negative.

    For the Harmonic Phases attribute, this value is the most recent phase of the given harmonic order

    in millidegrees (mDeg). A positive value indicates that the measured phase is leading, and a negative value indicates that the measured phase is lagging.

    If this measurement is not currently available, a value of null shall be returned.

    MatterSpecification.v13.Cluster § 2.13.5.3.2

  • order: FieldType<number>

    This field shall be the order of the harmonic being measured. Typically this is an odd number, but servers may choose to report even harmonics.

    MatterSpecification.v13.Cluster § 2.13.5.3.1

MatterSpecification.v13.Cluster § 2.13.5.3