Const
Readonly
attributes: { Readonly
minOn devices which support the AUTO feature, this attribute shall indicate the minimum difference between the Heat Setpoint and the Cool Setpoint.
Refer to Setpoint Limits for constraints. If an attempt is made to set this attribute to a value which conflicts with setpoint values then those setpoints shall be adjusted by the minimum amount to permit this attribute to be set to the desired value. If an attempt is made to set this attribute to a value which is not consistent with the constraints and cannot be resolved by modifying setpoints then a response with the status code CONSTRAINT_ERROR shall be returned.
Readonly
thermostatIndicates the running mode of the thermostat. This attribute uses the same values as SystemModeEnum but can only be Off, Cool or Heat. This attribute is intended to provide additional information when the thermostat’s system mode is in auto mode.
A ThermostatCluster supports these elements if it supports feature AutoMode.