This field shall specify the duration of time, in seconds, since a frame has been received from the Node for which this route table entry corresponds.
This field shall specify if the router ID as defined within the RouterId field has been allocated.
This field shall specify the IEEE 802.15.4 extended address for the Node for which this route table entry corresponds.
This field shall specify if a link has been established to the Node for which this route table entry
corresponds.
This field shall specify the implementation specific mix of IEEE 802.15.4 PDU receive quality indicators, scaled from 0 to 255, from the perspective of the Node reporting the neighbor table.
This field shall specify the implementation specific mix of IEEE 802.15.4 PDU receive quality indicators, scaled from 0 to 255, from the perspective of the Node specified within the NextHop field.
This field shall specify the Router ID for the next hop in the route to the Node for which this route table entry corresponds.
This Field shall specify the cost of the route to the Node for which this route table entry corresponds.
This field shall specify the RLOC16 for the Node for which this route table entry corresponds.
This field shall specify the Router ID for the Node for which this route table entry corresponds.
See
MatterSpecification.v13.Core § 11.14.5.5