Readonly
maxReadonly
measuredMeasuredValue represents the water content in % as follows:
MeasuredValue = 100 x water content
Where 0% < = water content < = 100%, corresponding to a MeasuredValue in the range 0 to 10000. The maximum resolution this format allows is 0.01%.
MinMeasuredValue and MaxMeasuredValue define the range of the sensor.
The null value indicates that the measurement is unknown, otherwise the range shall be as described in Measured Value.
MeasuredValue is updated continuously as new measurements are made.
Readonly
minThe MinMeasuredValue attribute indicates the minimum value of MeasuredValue that can be measured. The null value means this attribute is not defined. See Measured Value for more details.
Optional
Readonly
toleranceSee Measured Value.
The MaxMeasuredValue attribute indicates the maximum value of MeasuredValue that can be measured. The null value means this attribute is not defined. See Measured Value for more details.