MatterSpecification.v13.Cluster ยง 9.3.7.3

Enumeration Members

ContactDryFailure

The EVSE detected absence of voltage after enabling contactor.

ContactWetFailure

The EVSE detected voltage on charging pins when the contactor is open.

EmergencyStop

The emergency stop button was pressed.

EvDisconnected

The EVSE detected that the cable has been disconnected.

GroundFault

The EVSE has an unbalanced current supply.

LiveNeutralSwap

The EVSE detected Live and Neutral are swapped.

MeterFailure

The EVSE is unable to obtain electrical measurements.

NoError

The EVSE is not in an error state.

Other

Any other reason.

OverCurrent

The EVSE detected charging current higher than allowed by charger.

OverTemperature

The EVSE internal temperature is too high.

OverVoltage

The EVSE input voltage level is too high.

PilotShortCircuit

The EVSE pilot signal amplitude short circuited to ground.

PowerLoss

The EVSE has detected a loss in power.

PowerQuality

The EVSE has detected another power quality issue (e.g. phase imbalance).

UnderVoltage

The EVSE input voltage level is too low.

WrongPowerSupply

The EVSE could not determine proper power supply level.