Readonly
configUses an encoder for lift.
This bit shall indicate whether a position aware controlled window covering is employing an encoder for positioning the height of the window covering:
• 0 = Timer Controlled
• 1 = Encoder Controlled
The lift movement is reversed.
This bit shall indicate whether the lift movement is reversed:
• 0 = Lift movement is normal
• 1 = Lift movement is reversed
Supports the PositionAwareLift feature (PA_LF).
This bit shall indicate whether the window covering supports the PositionAwareLift feature:
• 0 = Lift control is not position aware
• 1 = Lift control is position aware (PA_LF)
Deprecated and reserved.
Device is operational.
This bit shall indicate whether the window covering is operational for regular use:
• 0 = Not Operational
• 1 = Operational
Uses an encoder for tilt.
This bit shall indicate whether a position aware controlled window covering is employing an encoder for tilting the window covering:
• 0 = Timer Controlled
• 1 = Encoder Controlled
Supports the PositionAwareTilt feature (PA_TL).
This bit shall indicate whether the window covering supports the PositionAwareTilt feature:
• 0 = Tilt control is not position aware
• 1 = Tilt control is position aware (PA_TL)
Optional
Readonly
currentIndicates the actual lift position (Unit cm, centimeters) of the window covering from the fully-open position.
Readonly
currentIndicates the actual position as a percentage with a minimal step of 0.01%. E.g Max 10000 equals 100.00%.
Optional
Readonly
currentIndicates the actual position as a percentage from 0% to 100% with 1% default step. This attribute is equal to CurrentPositionLiftPercent100ths attribute divided by 100.
Optional
Readonly
currentIndicates the actual tilt position (Unit 0.1°, tenths of a degree) of the window covering from the fully-open position.
Readonly
currentIndicates the actual position as a percentage with a minimal step of 0.01%. E.g Max 10000 equals 100.00%.
Optional
Readonly
currentIndicates the actual position as a percentage from 0% to 100% with 1% default step. This attribute is equal to CurrentPositionTiltPercent100ths attribute divided by 100.
Readonly
endThis attribute SHOULD provide more detail about the product type than can be determined from the main category indicated by the Type attribute.
The table below helps to match the EndProductType attribute with the Type attribute.
Readonly
installedIndicates the closed limit for lifting the window covering whether position (in centimeters) is encoded or timed.
Readonly
installedIndicates the closed limit for tilting the window covering whether position (in tenth of a degree) is encoded or timed.
Readonly
installedIndicates the open limit for lifting the window covering whether position (in centimeters) is encoded or timed.
Readonly
installedIndicates the open limit for tilting the window covering whether position (in tenth of a degree) is encoded or timed.
Readonly
modeThe Mode attribute allows configuration of the window covering, such as: reversing the motor direction, placing the window covering into calibration mode, placing the motor into maintenance mode, disabling the network, and disabling status LEDs.
In the case a device does not support or implement a specific mode, e.g. the device has a specific installation method and reversal is not relevant or the device does not include a maintenance mode, any write interaction to the Mode attribute, with an unsupported mode bit or any out of bounds bits set, must be ignored and a response containing the status of CONSTRAINT_ERROR will be returned.
Perform a calibration.
This bit shall set the window covering into calibration mode:
• 0 = Normal mode
• 1 = Calibration mode
Control the LEDs feedback.
This bit shall control feedback LEDs:
• 0 = LEDs are off
• 1 = LEDs will display feedback
Freeze all motions for maintenance.
This bit shall set the window covering into maintenance mode:
• 0 = Normal mode
• 1 = Maintenance mode
Reverse the lift direction.
This bit shall control the motor direction:
• 0 = Lift movement is normal
• 1 = Lift movement is reversed
Optional
Readonly
numberIndicates the total number of lift/slide actuations applied to the window covering since the device was installed.
Optional
Readonly
numberIndicates the total number of tilt actuations applied to the window covering since the device was installed.
Readonly
operationalIndicates the currently ongoing operations and applies to all type of devices.
Global operational state.
These bits shall indicate in which direction the covering is currently moving or if it has stopped. Global operational state shall always reflect the overall motion of the device.
Lift operational state.
These bits shall indicate in which direction the covering’s lift is currently moving or if it has stopped.
Tilt operational state.
These bits shall indicate in which direction the covering’s tilt is currently moving or if it has stopped.
Optional
Readonly
physicalIndicates the maximum possible encoder position possible (Unit cm, centimeters) to position the height of the window covering lift.
Optional
Readonly
physicalIndicates the maximum possible encoder position possible (Unit 0.1°, tenths of a degree) to position the angle of the window covering tilt.
Optional
Readonly
safetyThe SafetyStatus attribute reflects the state of the safety sensors and the common issues preventing movements. By default for nominal operation all flags are cleared (0). A device might support none, one or several bit flags from this attribute (all optional).
Communication failure to sensors or other safety equipment.
PCB, fuse and other electrics problems.
Actuator is manually operated and is preventing actuator movement (e.g. actuator is disengaged/decoupled).
Mechanical problem related to the motor(s) detected.
An obstacle is preventing actuator movement.
Device has failed to reach the desired position. e.g. with position aware device, time expired before TargetPosition is reached.
Device has power related issue or limitation e.g. device is running w/ the help of a backup battery or power might not be fully available at the moment.
Protection is activated.
Movement commands are ignored (locked out). e.g. not granted authorization, outside some time/date range.
Local safety sensor (not a direct obstacle) is preventing movements (e.g. Safety EU Standard EN60335).
Tampering detected on sensors or any other safety equipment. Ex: a device has been forcedly moved without its actuator(s).
Motor(s) and/or electric circuit thermal protection activated.
Does the device supports calibration?
Does the device supports maintenance mode?
Readonly
targetIndicates the position where the window covering lift will go or is moving to as a percentage (Unit 0.01%).
Readonly
targetIndicates the position where the window covering tilt will go or is moving to as a percentage (Unit 0.01%).
Readonly
typeThis attribute shall identify the type of window covering.
This attribute specifies the configuration and status information of the window covering.
To change settings, devices shall write to the Mode attribute. The behavior causing the setting or clearing of each bit is vendor specific.